Resistance thermometers (data sheet 8536)

Intrinsically safe


The resistance thermometer models TPtSrXiA and TPtSrXiAT with fabricated thermowells form 2, 2G and 2F according to DIN 43 772 have an EU Type Examination Certificate for the ignition protection type “intrinsic safety”. Both models meet the requirements of the directive 2014/34/EU for the application in potentially explosive atmospheres due to gases and dusts. The resistance thermometers can be mounted directly into the process. The measuring insert can be replaced as separate component.
For both models, we offer various measuring resistors according to DIN EN 60 751. In addition, model TPtSrXiAT is available with several fitted transmitters with analogue or digital output.
 
8536 Resistance thermometers TPtSrXiA intrinsically safe with fabricated thermowell according to DIN 43 772, measuring insert replaceable ARMANO

model TPtSrXiA / TPtSrXiAT
operating temperature range −200 / +600 °C (−328 / +1112 °F)
measuring insert replaceable
connection heads types XE-BUZ, XE-BUZ-H, XI-BUZ or XI-BUZ-H
degree of protection (DIN EN 60 529) IP67 with screwed cable gland (PAN, PAR, MAN or MAR)
approvals II 1G Ex ia IIC T6…T1 Ga
II 1/2G Ex ia IIC T6…T1 Ga/Gb
II 2G Ex ia IIC T6…T1 Gb
II 1D Ex ia IIIC T80 °C…T440 °C Da
II 1/2D Ex ia IIIC T80 °C…T440 °C Da/Db
II 2D Ex ia IIIC T80 °C…T440 °C Db
application in explosion hazardous areas zones 0, 1, 2, 20, 21, 22
output signal model TPtSrXiA:   resistance according to DIN EN 60 751
model TPtSrXiAT:  4…20 mA, HART® or PROFIBUS® PA / FOUNDATION™ Fieldbus